MODEL 2004

Vector Peristaltic Pump

Design Features

The best solution for difficult process fluids

  • Dry pump cavity
  • Self-priming operation
  • Runs dry without damage
  • Complete isolation of fluid pumped
  • Heavy-duty roller bearings
  • Variety of pump configurations, flows, and pressure ratings
  • No seals, cups or packing to leak or wear
  • Reversible flow
  • Low maintenance

Vector Pumps Resources

Model 2004 - Datasheets
Datasheets
Model 2004
(Performance, Dimensions, Options, Ordering Information)
Pump Selection
Design Considerations

Model 2004 - Specifications
Fluid Characteristics
Viscosity:15,000 cps max.
Liquid Temperature: 180°F (82°C) max.
Solid Size: (see Selection Guide)
Fiber Length:11/16 inch (17.4 mm) max.
Specifications
Discharge Pressure:45 psig (3 bar) max.
Suction Lift:14 ft. (4.3 m)
Suction Pressure:18 psig (1.2 bar) max.
Horsepower:*1/3 max.
Hose Size:17 x 31 x 590 mm
Displacement:0.0286 gal/rev
Weight (pump only):20 lbs. (9 kg)
Weight (with drive):34 lbs. (15.5 kg)

* Pumps are shaft driven and require a gearbox and motor.

Vector Pumps 2000-3000 Manuals
Vector Peristaltic Pump Installation and Operation Models 2002-2007
Entire Manual
Vector Peristaltic Pump Installation and Operation Models 2008-2010
Entire Manual
Vector Peristaltic Pump Installation and Operation Models 3005
Entire Manual
Hose Data

Vector pumps isolate the fluid being pumped into a single, durable hose so they can handle tough fluids.

Designed by the process industry for the process industry

When we say “Simply Built to Last”, we mean it!