MODEL 4003

Vector Peristaltic Pump

Design Features

The best solution for difficult process fluids

  • Dry pump cavity
  • Self-priming operation
  • Runs dry without damage
  • Complete isolation of fluid pumped
  • Heavy-duty roller bearings
  • Variety of pump configurations, flows, and pressure ratings
  • No seals, cups or packing to leak or wear
  • Reversible flow
  • Low maintenance

Vector Pumps Resources

Model 4003 - Datasheets
Datasheets
Model 4003
(Performance, Dimensions, Options, Ordering Information)
Pump Selection
Design Considerations

Model 4003 - Specifications
Fluid Characteristics
Viscosity:100,000 cps max.
Liquid Temperature: 180°F (82°C) max.
Solid Size: (see Selection Guide)
Fiber Length:2-3/8 inch (60 mm) max.
Specifications
Discharge Pressure:110 psig (7.6 bar) max.
Suction Lift (sea level):29.5 ft (9 m) max.
Suction Pressure:21.8 psig (1.5 bar) max.
NPSHr:4 ft
Horsepower:*0.75 max
Hose Size:10 x 32 x 570 mm
Displacement:0.0066 gal/rev
Lubrication Fluid:.37 qts (.35 L) max.
Lubricant:Glycerine / Glycol
Weight (pump only):22 lbs. (10 kg)
Weight (with drive):55 lbs. (25 kg)

* Pumps are shaft driven and require a gearbox and motor.

Vector Pumps 4000 Manuals
Vector Peristaltic Pump Installation and Operation Models 4000 Series
4000 Series O & I Manual

Vector pumps isolate the fluid being pumped into a single, durable hose so they can handle tough fluids.

Designed by the process industry for the process industry

When we say “Simply Built to Last”, we mean it!

TOP