Vector Peristaltic Pump Selection

Vector Peristaltic Pumps Capabilities Overview

Flow Capacities And Pressure Ratings

ModelMaximum Flow (gpm)Maximum Discharge Pressure (psig)
20020.330
20030.9430
20042.5245
20055.950
30059.2200
200614.160
200740.5100
200850100
2009120100
2010211116
40030.79110
40042.64110
400612.33218
400723.12218
400941.83218
401069.35218
4014154.1218

Maximum Allowable Solids Guidelines

Non-Compressible Solids
ModelHose I.D. (mm)Size of solids, when percentage of solids is >50% (mm)Size of solids, when percentage is <10% (mm)Sharp SolidsCompressible Solids (mm)
200291.352.25AVOID 8.1
2003131.953.25AVOID 11.7
2004172.554.25AVOID 15.3
2005253.756.25AVOID 22.5
3005304.57.5AVOID 27
2006456.7511.25AVOID 40.5
2007537.9513.25AVOID 47.7
20087511.2518.75AVOID 67.5
20091001525AVOID 90
2010253.756.25AVOID 22.5
4003101.352.25AVOID 8.5
4004152.13.9AVOID 14.5
4006253.756.25AVOID 22.5
4007324.57.5AVOID 28
4009406.110.9AVOID 39.5
4010517.512.9AVOID 46.5
40148012.119.5AVOID 69.5